4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
Bioclone Inc(授权代理)
主营:专注于生物磁分离技术的公司
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > > Bioclone/BcMag™ Quick HAS and IgG Depletion Kit/100x preps Kit/BF102
商品详细Bioclone/BcMag™ Quick HAS and IgG Depletion Kit/100x preps Kit/BF102
Bioclone/BcMag™ Quick HAS and IgG Depletion Kit/100x preps Kit/BF102
Bioclone/BcMag™ Quick HAS and IgG Depletion Kit/100x preps Kit/BF102
商品编号: BF102
品牌: Bioclone Inc
市场价: ¥13000.00
美元价: 7800.00
产地: 美国(厂家直采)
公司:
产品分类: 其他
公司分类:
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍

Workflow Of Quick HSA/IgG Depletion Kit

Work with the Albumin Removal Kit is straightforward. Mix the beads with serum or plasma samples and incubate them with continuous rotation. The beads remain suspended in the sample solution during mixing, allowing all other proteins in the sample (except albumin and IgG) to bind to the beads. After incubation, the beads are collected and separated from the sample using a magnet rack. Then the bound proteins are eluted.

Features and Advantages

Quick, Easy, eliminates columns, centrifuge, or filters

Remove >95% IgG and 90% Albumin

High throughput: Rapidly process up to 96 samples in less than 30 minutes

Low abundance enrichment is equal to or better than hexapeptides or antibodies

Mild elution preserves the tertiary structure and allows for easy transfer to secondary analysis

Scalable – easily adjusts for sample size and automation

Minimal sample dilution

Suitable for LC-MS, activity-based protein profiling, and proteomic research

PROTOCOL

Note

The following protocol is an example. Protein concentrations in serum might vary. Ten microliters of human serum have about 700µg of complete protein. About 70% of that will be human serum albumin and IgG. The amount of serum used in each response should be optimized by the user. Overloading the system may result in albumin carryover into the low abundant protein fraction. Using the given protocol, the user should expect a typical elution to include 50-100µg of serum protein.

The samples are eluted in a salt-containing buffer and may need to be desalted before electrophoresis or mass spectrometry analysis. If the sample is sufficiently diluted before analysis, desalting may not be required.

Materials Required

BcMag™ Quick HSA-IgG Depletion Magnetic Beads

1x Binding/Washing Buffer: 20 mM sodium phosphate, pH 6.5

1x Elution Buffer: 100 mM glycine-HCl, pH 2.7

Equipment

Item

Magnetic Rack for centrifuge tube


** Based on sample volume, the user can choose one of the following magnetic Racks

Source

•  BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

•  BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

•  BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

•  BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

Item

BcMag™ 96-well Plate Magnetic Rack.

Source

•  BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Item

Adjustable Single and Multichannel Pipettes

Item

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates / tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Eppendorf, Cat. No. 5353000529

Tube Holder PCR 96

Eppendorf, Cat. No. 022674005

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Eppendorf, Cat. No. 022674048

Smart Mixer, Multi Shaker

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR Plates/Tubes

** IMPORTANT! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.

Items

Magnetic Rack for centrifuge tube

** Based on sample volume, the user can choose one of the following magnetic Racks

Source

BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

BcMag™ 96-well Plate Magnetic Rack

BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Adjustable Single and Multichannel Pipettes

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates/tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048

BenchTop Lab Systems, Cat. No. 5353000529

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker
 

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048
 

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR Plates/Tubes

! IMPORTANT ! If using other tubes or PCR plates, ensure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.

Procedure

Note:

Vigorously shake the bottle until the magnetic beads become homogeneous.

Do not allow the magnetic beads to sit for more than 5 minutes before dispensing.

1.

Transfer 40 μl beads to a fresh tube or a new 96well PCR plate, Microplate, or 0.2ml PCR tube and add 50 μl binding buffer to a final 90 μL reaction volume.

2.

Add 10 μl serum sample and mix the sample with beads by slowly pipetting up and down 20-25 times, or Vortex the sample at 2000 rpm for 5 minutes (see picture).

3.

Place the sample plate/tube on the magnetic separation plate for 30 seconds or until the solution is clear.

4.

Discard the supernatant while the sample plate remains on the magnetic separation plate.

5.

Wash the beads with 100 μL of the binding buffer by slowly pipetting up and down 20-25 times, or Vortex the sample at 2000 rpm for 2 minutes. Place the sample plate/ tube on the magnetic separation plate for 30 seconds or until the solution is clear.

6.

Repeat step 5 once.

7.

Resuspend the beads in 50-100μl of Elution Buffer and mix the sample with beads by slowly pipetting up and down 20-25 times, or Vortex the sample at 2000 rpm for 5 minutes.

8.

Transfer the supernatant to a fresh microcentrifuge tube or microtiter plate well. The supernatant containing the proteins of interest is ready for downstream applications.

Learn More

Instruction Manual

MSDS

Sample Preparation Related Products →
品牌介绍
Bioclone的用于学术研究和治疗应用的重组蛋白/ DNA的数量已大大增加。然而,成功的重组蛋白表达取决于许多因素,例如密码子偏好性,RNA二级结构,异源表达系统中的GC含量。越来越多的实验结果证明,与预优化相比,取决于不同的基因,表达水平显着提高,从两倍提高到一百倍。Bioclone开发了一个独特的专有技术平台,并生成了超过14,000个人工合成的,经过密码子优化的cDNA / DNA克隆(克隆在大肠杆菌表达载体中,图1)和重组蛋白(在大肠杆菌酵母中生产)。Bioclone为所有cDNA克隆和重组蛋白生产提供即用型和基于客户的服务。特别设计和合成了数十万种重组蛋白和密码子优化的cDNA (DNA开放阅读框)。  密码子优化的cDNA / DNA:    产生更高产量的重组蛋白。将cDNA / DNA 克隆克隆到具有6x His -tag的大肠杆菌表达载体中,可立即用于重组蛋白生产。可以使用作为验证的RNAi的功能由于在其〜30%差的RNAi的援助cDNA序列时相比原的cDNA / DNA 。Bioclone 还提供客户服务克隆中的cDNA插入NY 所需的客户向量小号。重组蛋白:重组蛋白C 在N末端或C末端具有6x His-tag重组蛋白P roduced在大肠杆菌或小号F9昆虫细胞。  provid 我纳克准备使用的重组蛋白和p rotein点播服务的所有cDNA克隆。通过SDS-PAGE 测定的重组蛋白纯度> 90%。ř ecombinant蛋白应用:Western印迹,ELISA 或可以用于其它应用。  cDNA克隆和重组蛋白包括:我nfection疾病抗原(病毒,细菌,寄生虫,细菌毒素),抗过敏的蛋白质,细胞因子,   激酶,磷酸酶,信号转导,   干细胞和发展,神经科学, 药物   metabollism,普通的病,转录因子,癌症和更重组蛋白质和克隆是g 还是机翼.......