商品介绍

Sodium dodecyl sulfate is one of the most used detergents for solubilizing biological materials. Still, excess unbound detergent interferes with many downstream applications like mass spectrometry (MS) and amino acid sequencing, antigen-antibody binding, immunoprecipitation assay, and ELISA. Several SDS removal protocols, such as prolonged dialysis, anion exchange chromatography, spin column, and acetone precipitation, are routinely used. However, these procedures are either laborious or suffer from sample losses and are challenging for low volume samples and high thorough-put automation. We developed a novel, efficient SDS removal system to overcome these limitations.

BcMag™ One-Step SDS Removal Kit uses magnetic beads modified with proprietary chemistry to remove SDS detergent. The resin can quickly and efficiently remove free SDS (sodium dodecyl sulfate) from ultra-low volumes of protein/ peptide or DNA/RNA solutions. The beads enable 96 samples to be processed simultaneously in less than 10 minutes.

The beads allow rapid and efficient removal of free SDS from the sample. The procedure is straightforward (Fig.1). 1. Add the beads directly to the sample. 2. Pipette or vortex to capture the free SDS detergent. 3. Magnetic separation of the beads from the protein, or DNA/RNA solution, while the protein or DNA/RNA remains in the solution. The easy-to-use magnetic beads significantly improve results over the standard drip column and batch methodologies with minimum protein loss (<10%). Since only a small volume of magnetic beads is used, the final protein concentration of the sample is not significantly decreased.

Features and Advantages

Simple protocol: No liquid transfer, One-tube, One-step, and one-minute protocol

Easy-to-use

Reliable and reproducible results with exceptional >90% recovery for protein (>6 kDa, aprotinin) or DNA/RNA (>25mer dsDNA)

Effective Cleanup: Remove 95% free SDS detergent

Cost-effective: Eliminates columns, filters, and laborious repeat pipetting

High throughput: Compatible with many different automated liquid handling systems

PROTOCOL

Materials Required by the User

Item

Magnetic Rack for centrifuge tube


** Based on sample volume, the user can choose one of the following magnetic Racks

Source

•  BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

•  BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

•  BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

•  BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

Item

BcMag™ 96-well Plate Magnetic Rack.

Source

•  BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Item

Adjustable Single and Multichannel Pipettes

Item

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates / tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Eppendorf, Cat. No. 5353000529

Tube Holder PCR 96

Eppendorf, Cat. No. 022674005

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Eppendorf, Cat. No. 022674048

Smart Mixer, Multi Shaker

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR plates/tubes

** IMPORTANT! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.

Items

Magnetic Rack for centrifuge tube

** Based on sample volume, the user can choose one of the following magnetic Racks

Source

BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

BcMag™ 96-well Plate Magnetic Rack

BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Adjustable Single and Multichannel Pipettes

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates/tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048

BenchTop Lab Systems, Cat. No. 5353000529

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker
 

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048
 

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR Plates/Tubes

! IMPORTANT ! If using other tubes or PCR plates, ensure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.

Procedure

The following protocol is an example. The beads and sample volume can be rational Scale-up (or down). Do not use buffers containing organic solvents.

1.

Shake the bottle to resuspend the Magnetic beads until it is homogeneous entirely.

! IMPORTANT ! It is essential to mix the beads before dispensing. Do not allow the beads to sit for more than 2 minutes before dispensing. Resuspend the magnetic beads every 2 minutes.

2.

Add an appropriate amount of the magnetic beads to the sample containing free detergent.

! IMPORTANT ! Users need to optimize the beads and free detergents ratio based on the binding capacity (48 µg/mg beads**).** Binding capacity assay condition: Mix with 10 µl magnetic beads (100 mg/ml) with 100 µl protein sample (1:400 dilution of Human serum) containing detergents in 0.1M Sodium phosphate, 0.15M NaCl, pH7.5 buffer, and vortex at 2000 rpm for 5 minutes)

3.

Mix the sample with beads for 1-2 minutes by slowly pipetting up and down 20-25 times or vortex for 5 minutes at 2000 rpm for PCR plates or .800 rpm for microplates.

! IMPORTANT ! Users should optimize the speed and time if using a vortex mixer.

4.

Place the sample plate or tube on the magnetic separation plate for 30 seconds or until the solution is clear.

5.

Transfer the supernatant to a clean plate /tube while the sample plate remains on the magnetic separation plate. The sample is ready for downstream applications.

C. Troubleshooting

Problem

Low Protein Recovery

Probable Cause

Vortexing time is too long.

Suggestion

If using other digital vortex mixers, the vortex condition such as speed and time has to be optimized.

Problem

Low Protein Recovery

Probable Cause

Using too many magnetic beads

Suggestion

Completely resuspend the magnetic beads and reduce the amounts of the beads.

Problem

Failure to remove detergent.

Probable Cause

Used inappropriate tubes or plates

Suggestion

Ensure that the well diameter at the bottom of the conical section of the Tubes or well of the plate is ≥2.5mm.

Problem

Failure to remove detergent.

Probable Cause

Vortex speed is too slow, or vortex time is too short.

Containing too much SDS in the sample

Suggestion

  • Increasing either the speed or time
  • If using other digital vortex mixers, the vortex condition such as speed and time has to be optimized.
  • Repeat the procedure using more beads

Problem

Probable Cause

Suggestion

Low Protein Recovery

Vortexing time is too long.

If using other digital vortex mixers, the vortex condition such as speed and time has to be optimized.

Using too many magnetic beads

Completely resuspend the magnetic beads and reduce the amounts of the beads.

Failure to remove detergent.

Used inappropriate tubes or plates

Ensure that the well diameter at the bottom of the conical section of the Tubes or well of the plate is ≥2.5mm.

  • Vortex speed is too slow, or vortex time is too short.
  • Containing too much SDS in the sample
  • Increasing either the speed or time
  • If using other digital vortex mixers, the vortex condition such as speed and time has to be optimized.
  • Repeat the procedure using more beads

Learn More

Instruction Manual

MSDS

Sample Preparation Related Products →

General Reference

1.

Puchades M, Westman A, Blennow K, Davidsson P. Removal of sodium dodecyl sulfate from protein samples before matrix-assisted laser desorption/ionization mass spectrometry. Rapid Commun Mass Spectrom. 1999;13(5):344-9.

2.

Ilavenil, S., Al-Dhabi, N.A., Srigopalram, S. et al. Removal of SDS from biological protein digests for proteomic analysis by mass spectrometry. Proteome Sci 14, 11 (2016).

3.

Oscar H. Kapp, Serge N. Vinogradov, Removal of sodium dodecyl sulfate from proteins,Analytical Biochemistry,Volume 91, Issue 1,1978.

4.

Doucette, and A. Crowell, “Precipitation of Detergent-Containing Samples for Top-Down and Bottom-Up Proteomics”, in Proteomics Technologies and Applications. London, United Kingdom: IntechOpen, 2019, Pages 230-235

5.

Hou, H., He, H. & Wang, Y. Effects of SDS on the activity and conformation of protein tyrosine phosphatase from thermus thermophilus HB27. Sci Rep 10, 3195 (2020).

6.

Sun D, Wang N, Li L. Integrated SDS removal and peptide separation by strong-cation exchange liquid chromatography for SDS-assisted shotgun proteome analysis. J Proteome Res. 2012 Feb 3;11(2):818-28.

品牌介绍
Bioclone的用于学术研究和治疗应用的重组蛋白/ DNA的数量已大大增加。然而,成功的重组蛋白表达取决于许多因素,例如密码子偏好性,RNA二级结构,异源表达系统中的GC含量。越来越多的实验结果证明,与预优化相比,取决于不同的基因,表达水平显着提高,从两倍提高到一百倍。Bioclone开发了一个独特的专有技术平台,并生成了超过14,000个人工合成的,经过密码子优化的cDNA / DNA克隆(克隆在大肠杆菌表达载体中,图1)和重组蛋白(在大肠杆菌酵母中生产)。Bioclone为所有cDNA克隆和重组蛋白生产提供即用型和基于客户的服务。特别设计和合成了数十万种重组蛋白和密码子优化的cDNA (DNA开放阅读框)。  密码子优化的cDNA / DNA:    产生更高产量的重组蛋白。将cDNA / DNA 克隆克隆到具有6x His -tag的大肠杆菌表达载体中,可立即用于重组蛋白生产。可以使用作为验证的RNAi的功能由于在其〜30%差的RNAi的援助cDNA序列时相比原的cDNA / DNA 。Bioclone 还提供客户服务克隆中的cDNA插入NY 所需的客户向量小号。重组蛋白:重组蛋白C 在N末端或C末端具有6x His-tag重组蛋白P roduced在大肠杆菌或小号F9昆虫细胞。  provid 我纳克准备使用的重组蛋白和p rotein点播服务的所有cDNA克隆。通过SDS-PAGE 测定的重组蛋白纯度> 90%。ř ecombinant蛋白应用:Western印迹,ELISA 或可以用于其它应用。  cDNA克隆和重组蛋白包括:我nfection疾病抗原(病毒,细菌,寄生虫,细菌毒素),抗过敏的蛋白质,细胞因子,   激酶,磷酸酶,信号转导,   干细胞和发展,神经科学, 药物   metabollism,普通的病,转录因子,癌症和更重组蛋白质和克隆是g 还是机翼.......